Central Building Services & Utilities — ICD

WHSG Thermal Interface ICD
REG-WHSG-001 ↔ T2 Processing Thermal Loads

Interface Control Document — Process Gas Heat Recovery Unit → T2-ITD LCI thin-film evaporator + PRE-EVP-001 Liquifact™ evaporators. Physical tie-in at RMB→PIMB thermal header wall penetration.

Doc No.CBT-ICD-WHSG-T2-001
RevisionRev 0
StatusWORKING DOCUMENT — 1st Review Draft
Date2026-07-08
ClassificationISC-2 Confidential
⚠ WORKING DOCUMENT — 1st Review Draft
Pre-Release Engineering Development. Content authored by Designer 2026-07-08 for first review. OPEN and parametric values preserved verbatim — no fill or invented values. PE sign-off not authorized. Refer to source draft designer-drafts/CBT-ICD-WHSG-T2-001_rev0_draft.md.

1. Scope & Interface Boundary

Defines the thermal interface between REG-WHSG-001 (NXS-Z2 high-temperature thermal recovery) and the T2 Processing steam/thermal-oil loads (T2-ITD LCI thin-film evaporator dryer; PRE-EVP-001 Liquifact™ evaporators). Physical tie-in at the RMB→PIMB thermal header wall penetration.

Terminology
REG-WHSG-001 is a Process Gas Heat Recovery Unit fed by hot process gases from the upstream MCR train — never "boiler" / "steam generator" (D-65 firewall lock).

2. Interface Register

IDInterfaceMediumParameterStatus
WHSG-T2-01NXS-Z2 thermal outputSteam OR thermal oil200–400°C / 10–40 bar (steam) or 200–400°C / 1–5 bar (oil) — parametric basis: T2-ITD envelope (TDS-004 Rev 3 §5.3) + PRE-EVP-001 (TDS-005). OER Gate 2 WHSG OEM confirmation.OPEN
WHSG-T2-02NXS-Z2 thermal duty @ 400 TPD2–8 MW thermal equiv. — parametric basis: D-35. OER Gate 2.OPEN
WHSG-T2-03Condensate returnWaterDEFINED — closed loop, zero-dischargeDEFINED
WHSG-T2-04ConnectorFlangedASI-WTR-001 class / ASI thermal flange — confirm sizingOPEN

3. Heat Balance Basis

Source: MCR process gas enthalpy (Recyclotron™ train). CSC load = independent (D-65 = dedicated 915 MHz microwave; does NOT draw on WHSG). Magnetron draw 11.52 MW (D-30). Available NXS-Z1 balance ≤20.48 MW. WHSG recovers process-gas sensible heat only — no independent fired source.

4. Control & Instrumentation

SCADA via ASI-DAT-MOD-TCP (Modbus TCP/IP). Interlocks: OPEN — SCADA tag list (ties to ICD-A05).

5. Steam Scaling (per T2 demand)

TPDT2 steam demand
10080 kg/hr
500430 kg/hr
1,000880 kg/hr

Source: CBT-PRE-OER-AMD-001 Rev 1 Table C-1.

6. Open Actions

7. Interface Ownership

REG side: Carbotura OEM. T2 side: Carbotura OEM. Integration/FAT: ASI.

END OF DRAFT — CBT-ICD-WHSG-T2-001 | Rev 0 | 2026-07-08 | CONFIDENTIAL — CARBOTURA INC.